Understanding Digital Buses: s88, LocoNet, XpressNet and CAN
Control, feedback and networking: find out which bus suits your task and why the exact command station makes a difference.

What does each bus do?
s88 collects feedback, XpressNet mainly connects control devices, and LocoNet links various control functions. CAN provides the technical basis for several manufacturer-specific systems. What matters is therefore not which bus is supposedly best, but which connection on your command station supports the intended task with the chosen device.
A digital bus carries messages between devices. This differs from the DCC, Motorola or mfx signal on the track. A DCC locomotive does not need a LocoNet connection simply because you control it with a LocoNet handheld controller. The command station links the controls to the track signal. This basic relationship applies to H0, TT, N and larger gauges; power and track voltage must also suit the layout.
| Bus | Typical task | Arrangement and important limitation |
|---|---|---|
| s88 / s88-N | Transmit contact states and occupancy for processing. | An ordered chain of modules. s88-N uses RJ45 but is not Ethernet; check voltage and module direction. |
| LocoNet | Connect handheld controllers, feedback modules, input/output devices and interfaces. | Chains, stars and branches are possible; no closed ring. Check the socket version and power supply. |
| XpressNet / X-BUS | Connect control devices and interfaces to the command station; also transmit status information. | Follow the device’s wiring plan. Check addresses and supported commands; not a universal direct connection for track detectors. |
| CAN systems | Depending on the manufacturer, tasks may include control, feedback and booster communication. | Message format, connections, power supply and termination are system-specific. Consider Märklin and Z21 separately. |
s88 and s88-N: feedback from the layout
Feedback modules detect contact tracks, push-buttons or the state of upstream occupancy detectors, for example. With classic s88, these states are read through a chain of modules. The position in the chain and configured number of inputs determine the assignment. Adding a module at the front can shift subsequent contact numbers.
s88-N standardises the connection through eight-pin RJ45 connectors and network cables. This makes wiring easier, but does not turn s88 into a computer network. Do not place a network switch between s88-N modules. Also check the permitted bus voltage: an existing module may be designed for 5 V, while another connection operates at 12 V.
The input type matters: a contact detector and a module with built-in current sensing perform different tasks. The bus name alone does not tell you whether a particular two-rail track section can be connected directly. The basics of track occupancy detection explain how to choose sensors.



LocoNet: control, feedback and switching
LocoNet allows several types of device to exchange messages. Depending on the equipment, these include handheld controllers, feedback modules, input/output modules and computer interfaces. Devices can report events; this differs from the continuously read s88 chain.
Branches are useful when planning a layout: Digitrax describes chains, stars and tree structures. Do not form a closed ring. Use LocoNet cables with the correct pin assignments and distributors intended for your devices. A telephone cable that physically fits is not necessarily a suitable bus cable.
Socket versions are particularly important. LocoNet-T and LocoNet-B differ in areas including the outer conductors and power supply or RailSync. The black Roco Z21 provides LocoNet-T without RailSync; this does not make it a general-purpose LocoNet booster connection. The approvals for the command station and accessories remain decisive.


XpressNet and X-BUS: connecting control devices
XpressNet originates from Lenz. Typical devices include handheld controllers, button modules and interfaces. Roco calls the corresponding connection X-BUS. A wired multiMAUS controller is a clear example. Communication takes place with the command station, so device addresses and supported commands belong in the plan.
XpressNet can also pass on status and feedback information. This does not mean any track occupancy detector can be plugged into it. With Lenz, feedback from modules designed for that purpose reaches the command station through the separate RS-Bus. The command station distributes the information to suitable XpressNet devices.
When combining manufacturers, the specific device version, firmware and cable pin assignments matter. A compatible basic function does not guarantee every special function. Build connections and branches according to the relevant wiring diagram. The Z21 product overview also helps distinguish between the wired multiMAUS and WLANMAUS.


CAN: a shared basis, different systems
CAN is a robust technology for exchanging messages. Model railway manufacturers build their own devices and message formats on this basis. The Märklin system bus and Roco Z21-CAN must therefore not be treated as freely interchangeable connections. Connectors, power supply and network termination also form part of each implementation.
In the Märklin system, for example, Link S88 connects s88 feedback to a supported Central Station. In the Z21 system, suitable CAN detectors can transmit further information, such as supported RailCom data, as well as occupancy. RailCom here refers to feedback from the vehicle through the track; CAN is the subsequent transmission path in the relevant system.
Distributors and hubs must be expressly suitable for that system. A blanket rule to “add two terminating resistors somewhere” is unsuitable for ready-made model railway components: termination may be integrated or provided through the specified components. Follow the manufacturer’s plan.
Which connections does your command station provide?
This selection shows specific connection options. A bus socket does not mean every similarly named accessory is approved. R-BUS and RS-Bus are included in the overview because they are important for feedback in the systems listed.
| Command station / generation | Control and expansion | Feedback and particular features |
|---|---|---|
| Black Roco Z21, 10820 | X-BUS, supported LocoNet devices; Z21-CAN for suitable components. | R-BUS, approved LocoNet devices and Z21-CAN. LocoNet-T without RailSync. |
| White Roco z21 / z21start, older generation | X-BUS; network control depending on activation and equipment. | R-BUS; no built-in LocoNet or CAN sockets. |
| Roco Z21 START newGen | One X-BUS socket and integrated Wi-Fi. | No documented wired feedback bus. USB-C is a charging port; do not equate it with the older z21start. |
| Märklin CS3 60226 / CS3 plus 60216 | Märklin system bus with components approved for it. | CS3: s88 through Link S88. CS3 plus: also a direct s88 connection underneath. Check the permitted voltage. |
| Lenz LZV200 | XpressNet for handheld controllers and suitable interfaces. | Suitable feedback modules on the separate RS-Bus; the command station passes information on to XpressNet. |
| Uhlenbrock Intellibox 2neo | LocoNet-T and LocoNet-B with different functions. | LocoNet and s88-N provided. Use the specific 2neo instructions; do not apply them indiscriminately to other generations. |
Check the device name and generation on the identification plate. Functions may also depend on the firmware version. This overview does not replace the wiring instructions for the chosen device.


Narrow down the right connection
Choose your command station and intended task. The guide suggests a sensible starting point for further checks. It does not confirm that any arbitrary device combination will work.
Start with the exact command station
Compare the model name, available socket and intended task in the command station overview. Only then choose the device and cable.
Go to the command station overviewPlan and test the wiring
First draw the command station, operating positions, feedback modules and any interfaces. Label every cable route with the full bus name. On sectional layouts, include plug connections between sections and strain relief in this plan. A dedicated connector type or clear labelling helps prevent mix-ups.
Keep bus cables separate from heavily loaded track and switching cables wherever possible. Check the power supply, cable length and number of devices against the equipment documentation. General cable lengths for all systems would be misleading. Supplement the basics of layout wiring with a documented bus plan.
Principle diagrams without pin assignments. Follow the manufacturer-specific layout plans for XpressNet and the various CAN systems.
Example: commissioning an s88 chain step by step
Suppose a hidden storage yard is initially to be monitored with one compatible feedback module. You need the approved connection or a suitable interface, the module, bus cable and suitable sensor wires. An existing track section also needs isolation appropriate to the detector.
Start with one module and a short cable
Switch off the power supply in accordance with the manufacturer’s instructions before changing connections. Check the connection direction, module voltage and sensor wiring. Then configure the correct interface, number of modules and number of inputs in the command station or software. Add the next module only once operation is reliable.
Test only the first feedback input initially
Trigger the input with its intended contact or a suitable electrical load. Do not connect unknown terminals together as a test. Record the input, module position and software address together; this documentation makes later expansion easier.
Check the expected indication on the track diagram
Exactly the assigned symbol must respond and return to the appropriate state after the event ends. With a current-sensing detector, a vehicle needs a detectable current draw. An unlit coach or wagon without an electrical load may remain unreported even when the bus works correctly.
Trace faults from the connection to the display
Change only one thing at a time. Start with a cable known to work and a single device. Add distributors, further modules and longer cable routes only when this small combination operates reliably.
| Symptom | Possible cause | Next check |
|---|---|---|
| No device responds | Wrong socket, missing power supply or unsuitable cable. | Test with an approved device and a short cable known to work, connected directly to the designated port. |
| Incorrect contacts after expansion | s88 order, number of inputs or address assignment changed. | Compare the module list and software configuration. Test the newly added part on its own. |
| Reports flicker or drop out | Power supply, cable contact, cable routing or unsuitable termination. | Reduce the setup to a short connection; check the power supply and wiring requirements. |
| Device fits physically but does not work | Wrong protocol, missing approval or unsuitable firmware. | Compare both device manuals. A socket adapter does not replace protocol translation. |
A multimeter helps check power supplies and unpowered cables, but does not show the contents of bus messages. Use the designated diagnostic displays or manufacturer software for this. Find out more in troubleshooting with a multimeter.
Common questions about digital buses
Can I use several bus systems at the same time?
Yes, if the command station or interfaces support the chosen connections. Handheld controllers and feedback modules may use different paths, for example. Software assignments, addresses and power supplies must be clearly documented.
Can an adapter convert s88 to LocoNet?
An active interface designed for the purpose can transfer reports between systems. A simple plug adapter only changes the connection. Check the transmission direction, supported reports and required power supply.
Does DCC compatibility also mean bus compatibility?
No. DCC here describes communication on the track. Whether a handheld controller, feedback module or bus distributor suits the command station must be checked independently.
How many devices can connect to a bus?
The command station, bus version, device addresses, cabling and power budget determine this together. A permitted number of addresses does not automatically mean the socket can supply enough current for all connected devices.
Why is no feedback shown despite a correct bus connection?
The sensor type, input address and software assignment must be correct as well as the connection. First check whether the module itself detects the event. This separates a track problem from a transmission problem.
Manufacturer documents and further sources
Use the documentation for the relevant devices and system generation for the actual wiring.
- RailCommunity: RCD-688 – s88-N, edition 6 December 2020 (in German)
- LDT: RM-GB-8-N – instructions and bus voltage
- Digitrax: LocoNet Overview and wiring
- Lenz: XpressNet protocol version 4.0 (in German)
- Lenz: LZV200 – operating instructions V4.0
- Roco: black Z21 – connections
- Roco: older white z21 and z21start – connections
- Roco: Z21 START newGen – manual VIII/2026
- Roco: Z21 FAQ – X-BUS, LocoNet-T and RailSync
- Roco: Z21 CAN HUB 10804 – instructions
- Roco: Z21 Detector 10808 – R-BUS and CAN
- Märklin: Central Station 3, 60226
- Märklin: Central Station 3 plus, 60216
- Uhlenbrock: Intellibox 2neo – manual (in German)
Find handheld controllers, feedback modules and bus accessories
Choose the appropriate system group and compare the exact device names. A CAN component for Z21, a Märklin module and an ESU ECoSlink device belong to different systems. The grouping is a guide, not a blanket compatibility approval. Check the connection, power supply and manufacturer’s instructions before choosing.
Find suitable products through the links to the range.